Home > Product Category > Execution and auxiliary equipment > SFD accident pressure distribution section closing device

SFD accident pressure distribution section closing device

1. Overview

The SFD accident pressure distribution sectional closing device integrates the accident pressure distribution valve and the sectional closing valve. It is used in the speed control system of the hydropower generator set in the hydropower station to prevent the unit from overspeed and water hammer, and is the normal operation of the hydroturbine generator set. Operation provides safe and reliable protection.

Through the optimized design of this product, all components are connected by plate plug-in, which has a high degree of integration, good sealing performance, convenient installation, debugging and maintenance, small size and reliable operation.

2. Technical parameters

Rated pressure: 2.5MPa 4.0MPa 6.4MPa

Power supply voltage: 220VDC, 220VAC

Output contact: SPDT   

Contact capacity: 5A/AC220V

Ambient temperature: 5~40℃     

Relative humidity: ≤95%RH

Installation method: horizontal and vertical installation

Connection method: flange connection, flange standard: GB9119-2000

3. Dimensions

a19-sfd Accident Pressure Distribution Sectional Closure Device 0003_copy.jpg

 


Copyright  ©  2021-  Baoji Xirui Hydropower Automation Technology Co.,Ltd.  All Rights Reserved. 陕公网安备61030302000395号