1. Overview
TCS thermal conductivity flow switch is an electronic product developed for the cooling water system of hydropower station and the flow monitoring and control of lubrication system. This product is based on the principle of thermal diffusion, which improves the traditional mechanical products such as complex structure, easy drift of setting value and unstable state of small flow. It can be applied to various medium flow monitoring occasions.
2. Technical parameters
Working medium: oil, water, gas.
Scope of application: oil 0-10m/s; water 0-5m/s; gas 0-50m/s
Response time: typical 2s, maximum 8s
Repeatability: ±1% of set point span
Applicable pipe diameter: DN15-DN300
Working voltage: DC24V
Current consumption: ≤65mA
Pressure rating: 10Mpa
Medium temperature range: -25℃-80℃
Connection method: G1/2 (with welding seat, welding seat inner thread G1/2)
Housing protection: IP67 protected stainless steel housing
Output form: relay
3. Panel and external dimensions
4. Electrical connection